2-Port USB 2.0 to RS-232 DB-9 Industrial Serial Adapter w/ 25kV ESD & 2kV Optical Isolation Protection

Model No. USB-2COM-SI-M

RS-232 | 256 Bytes Receive | 128 Bytes Transmit

  • Superior Build Quality: Housed in a rugged steel chassis with built in mountable flanges, the serial adapter hub is perfect for installations in labs, warehouses, or heavy machinery.
  • Safe Industrial Connections: Designed for use with Bar Code Scanners, Time Clocks, Label & Receipt Printers, and other legacy devices the USB to Serial Adapter offers 25kV surge protection for connected devices.
  • Expand Your Serial Capabilities: Connect 2 legacy 9-pin serial device through a USB-A port to add legacy functionality to newer technologies with no serial port connections.
  • COM Retention: COM Ports are fully configurable, and after reboots, port assignments are preserved.
  • USB Power: Power is drawn from a USB connection, no bulky power supply or power outlet is required. 
  • Upstream: 1 USB port, Type B Female Connector
  • Downstream: 2 Male DB9, w/ nuts
  • LEDs: Power, TX / RX

$149.89

Bulk Pricing

Model No. USB-2COM-SI-M

In stock

Volume Pricing

Units Discount Price
1 - 4 $149.89
5 - 11 3 % $145.39
12 - 24 5 % $142.40
25 - 49 7 % $139.40
50+ 10 % $134.90
Need some help? Contact us.

Sofware & Drivers

Quick Links:

Description

Introduction:

The USB-2COM-SI-M USB Serial Adapter simplifies serial port expansion, allowing you to quickly add 2 serial communication ports to your system by connecting it to a USB port on your computer or hub. With plug-and-play functionality and hot-swapping capabilities, this adapter makes it easy to integrate legacy serial devices without the usual setup headaches. In addition, the USB Serial Adapter safeguards connected equipment with 200V DC optical isolation and 25kV ESD surge protection, ensuring reliable performance in harsh environments.

Once connected, the adapter is automatically detected by your system, with no need for extra resources like IRQs or memory allocation. The DB9 RS-232 ports functions as a native Windows COM ports, offering full compatibility with Windows serial communication applications, and each port is individually configurable to meet specific system requirements.

Built for industrial and commercial use, the USB Serial Adapter provides reliable RS-232 connectivity for devices such as factory automation equipment, barcode scanners, time clocks, and data collection tools. It’s ideal for high-speed communication in demanding environments like manufacturing, remote access setups, and data-driven applications.

Features:

  • Adds two high speed RS-232 serial port by connecting to a USB port
  • 2000V DC optical isolation for all signals
  • SECC metal chassis suitable for DIN rail mounting
  • Powered by USB port, no external power adapter required
  • LEDs indicate TxD and RxD for easy port monitoring and diagnosis
  • Installs as a standard Windows COM port
  • Full RS-232 modem control signals and hardware/software flow control
  • Serial port protected with surge protection of 25kV
  • Non-standard baudrates supported
  • Easy plug and play installation and RS-232 device connection
  • High speed serial port with baud rate up to 1Mbps

OS Support:

  • Supports Windows XP to 11, Server 2000 to Server 2022 (WHQL certified)
  • Supports Linux Kernel 3.0 and above
  • Supports Mac OS X 10.3 and above

Package Contents:

  • 2 Port USB to Serial RS-232 DB-9 Adapter Device
  • 3 foot USB A to B cable
  • Driver Disc/Manual

*Surface Mounting screws not included.

Specifications

Product Specifications

Power
External Power Required

No

Compliance
Country of Origin

Taiwan

Physical Characteristics
Color

Black

Mounting Style

Desktop

Ports

2 Serial Ports

Material of Construction

Steel

Screw Lock Compatible

Yes

Serial Attributes
RS Signals

DCD, RxD, TxD, DTR, GND, DSR, RTS, CTS, RI

Serial Standards

RS232

Baud Rate

921.6K bps

FIFO Receive

256 bytes

FIFO Transmit

128 bytes

Data Bits

7, 8

Parity

None, Even, Odd, Mark, Space

Stop Bits

1, 2

Flow Control

Hardware (RTS, CTS), XON/XOFF

Software
OS Support

Win 11, Linux, Mac OSX, Win 10, Win 7, Win 8

Environmental
Operating Temperature

0°C to 55°C (32°F to 131°F)

Storage Temperature

-20 to 75°C (-4 to 167°F)

Humidity

5% ~ 95% (non-condensing)

Product Information
Warranty

1 year from date of purchase

Hardware
LED Indicators

Power, TX / RX

Upstream USB Ports

1 Type-B Female USB

Performance & Safety
ESD Protection

25kV Surge Protection

Other Data
Connector

DB9 Male w/ Nuts

Warranty

1 year from date of purchase

USB Interface

USB 2.0

Weight

.65 lbs

Dimensions

5 × 4 × 2.5 in

UPC: 729440690755
Optional Accessories

Replacement Parts & Accessories

DIN Rail Mount Gives DIN Rail Mounting capabilities to USB to serial adapters, IP Adapters, or Ethernet servers that are designed for mounting applications. For…

Model# DIN-RAIL-CLIP

$8.95

In stock

Support

Product Documentation & Drivers

Sofware & Drivers


Need drawings, CAD files, or other compliance documentation? Click HERE

Serial F.A.Q.

Product F.A.Q.

View frequently asked product questions below. For all serial troubleshooting, visit this page.
Still need help? Reach out!

  • How do I clean and reinstall my FTDI drivers?
      1. Download the CDM Uninstaller HERE.
      2. Extract the zip file, or open the “CDMuninstallerGUI.exe” utility.
      3. Leave the ‘Vendor ID’ set to 0403 and ‘Product ID’ set to 6001.
      4. Click Add.
      5. Click Remove Devices.
      6. Download the corresponding driver for your operating system and follow on-screen prompts. Windows Driver | MacOS Driver

    Video tutorial here.

  • How can I change my device’s COM port?
      1. Click on Start and navigate to the Control Panel
      2. Locate and click on Device Manager
      3. Under “Ports (COM & LPT)” you will find your serial device titled “USB Serial Port” along with its current COM Port.
      4. Right click on “USB Serial Port” and click on Properties.
      5. Navigate to the “Port Settings” tab and click on “Advanced…”
      6. Once there, the “COM Port Number:” can be changed with a dropdown menu to select the port number.
      7. Click your desired port number (i.e. COM2) and click “OK”.
      8. Click “OK” once more.
      9. Your serial device is now assigned to your chosen COM Port.

     

  • How do I check to ensure the COM port is listed properly in Windows?
    To ensure your serial device is installed properly, complete the following:

    1. Press Windows Key + R to open the Device Manager. Once Run comes up, type “devmgmt.msc” into the text field and press Enter.
    2. Expand the section labeled, Ports (COM & LPT).
    3. You should now see a COM number in brackets to the right of each port. If the device is installed properly, no exclamation points or question marks should be present next to the device.
  • I have everything hooked up, but nothing is functioning correctly.
    To rule out potential issues, quickly test your individual components to ensure that they are working correctly individually, and are not the source of the problem:

    • Serial cables
    • Serial ports
    • Serial devices

    Test your components by:

    • Hook up the serial cable(s), serial port(s), and serial device(s) in a different setup to see if the issue stems from a particular component, or the setup as a whole.
    • Replace the serial cable, port, or device within your setup to further troubleshoot the issue’s origin.

    When testing cables:

    • Test each cable individually.
    • Use short cables when you are testing.

    When testing serial ports and devices:

    • Press the Windows key + R, in Run, type devmgmt.msc, and press Enter to open the Device Manager. You can then check to see if your device is listed under Ports (COM & LPT).
    • Ensure that the COM port number is the correct number for the serial device and that the software being used to connect the computer to the serial device uses the correct COM port number.
    • If the device is listed with an error, follow the instructions on the website to reinstall the drivers.
  • Serial communication is not functioning correctly, how can I tell if the problem caused by the adapter or my serial software application?
    Older serial communication applications make use of legacy hardware addresses, often incompatible with PCI, PCIe, and USB to Serial products. Contact the software provider to troubleshoot.
  • I am receiving an error when I try to install the drivers in Windows 8 64 bit.
    Driver Signature Enforcement in Windows 8 may need to be disabled in order to use various drivers. After disabling this feature, the driver will be allowed to install.

    Note: You are required to restart your computer after disabling the Driver Signature Enforcement. Save all open work on your computer.

    Disable driver signature enforcement:

    1. Press the Windows key + C.
    2. Click Settings > Change PC Settings.
    3. In the left pane, click General.
    4. In the right pane, under Advanced startup, click Restart now.

    When your system restarts:

    1. Click Troubleshoot > Advanced options > Startup Settings > Restart.
    2. Press 7.

    When your computer restarts, Driver Signature Enforcement will be disabled and you can install the drivers.

  • I am receiving an error when I try to install the drivers in Windows 10 64 bit.
    Driver Signature Enforcement in Windows 10 may need to be disabled in order to use various drivers. After disabling this feature, the driver will be allowed to install.

    Note: You are required to restart your computer after disabling the Driver Signature Enforcement. Save all open work on your computer.

    Disable Driver Signature Enforcement:

    1. Click the Windows icon in the taskbar.
    2. Click Power.
    3. Press and hold the Shift key and click Restart.

    After your computer restarts:

    1. Click Troubleshoot Advanced Options Startup Settings Restart.
    2. Press 7.

    When your computer restarts, Driver Signature Enforcement will be disabled and you can install the drivers.

  • Why did the software not install properly in macOS High Sierra (10.13) or later?
    High Sierra 10.13 and later versions of macOS enforce strict security policy revisions. In order for the device to operate, software packages like those used in this installation must be allowed in macOS Security and Privacy settings once the software is installed.

    Once the driver/software is installed, follow these steps to allow the software:

    1. Open System Preferences.
    2. Open Security & Privacy.
    3. Click the Allow button near the bottom of the General tab.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “2-Port USB 2.0 to RS-232 DB-9 Industrial Serial Adapter w/ 25kV ESD & 2kV Optical Isolation Protection”